Connection operations

Gateway administrators manage shared connections in the Designer's Connections workspace. Named queries belong to projects; their connection IDs point at the shared gateway configuration.

Lifecycle

  • Save connection accepts new IDs without a revision. Existing entries must send their current revision; a stale or missing revision returns HTTP 409 without changing saved configuration. Reload discards local edits and fetches the current entry.
  • Renaming preserves the connection ID and its references. Changing the connector type requires a new connection.
  • Connection enabled takes effect when saved. Disabling immediately invalidates OPC UA subscription callbacks, cancels their watches and reports Bad_Disabled on bound tags. The last value remains available with bad quality; it is not represented as current good data.
  • Disabled entries block new tests, browse calls, schema/database operations and query operations when they resolve the connection. An operation admitted before disable may finish; disabling is not a transaction rollback or an emergency equipment stop.
  • Re-enabling preserves tags and named-query references. Tag subscriptions reconnect normally. The saved test result is cleared on every configuration save, including rename, disable and re-enable; test again against the new revision.
  • Existing records with no revision or enabled load as revision 0 and enabled. Saving upgrades that entry in place. Password omission preserves the encrypted password; an explicit empty password clears it.

Deletion is not available in this increment. Dependency observations are not an atomic lock across project drafts, publications and scripts. A safe deletion workflow remains on G05's roadmap.

Tests and observations

Test connection performs a read check, then stores the start/completion timestamps, duration, success and configuration revision in connections.json. It does not continuously monitor health. The latest-started test is the only overlapping test allowed to update status, and a test captured before a configuration save cannot overwrite the newer entry. Canceled tests do not overwrite the last completed result.

Stored results use fixed messages for success, missing managed SQLite databases, OPC UA authentication/security failures or a generic failure. Raw exception messages, passwords and connection strings are not persisted in diagnostics. Connections still retain their normal protected credentials in the gateway store.

Dependencies and tag values shows an administrator-only, read-only snapshot:

  • Gateway tag definitions referencing the connection.
  • Named queries in every current project draft and published query snapshot, including archived projects and published script-only named queries. SQL text is not returned. Scripts may choose a connection dynamically; such references cannot be inferred from this list.
  • OPC UA subscription state and last notification time.
  • Up to 100 configured tag values with quality, type and source timestamp. Values longer than 512 characters are shortened. The source timestamp describes a value notification and can remain old when a value does not change.

The panel marks its snapshot stale after 30 seconds using time elapsed in the browser. Refresh diagnostics refreshes the gateway snapshot; it does not create an extra OPC UA read or write session. Up to 500 references are shown with explicit omitted counts. A save or a selection change clears older UI results; a mismatched configuration revision requires Reload.

Endpoint discovery and certificate fingerprint selection remain available for OPC UA clients. This increment does not add certificate store administration, a delete API, continuous SQL health polling or equipment writes.

Workshop: SQLite lifecycle and dependencies

Use the SQLite data controls setup workshop from examples/catalog.json on a disposable gateway. This is a gateway-setup example, not a self-contained .sparkproj; its database connection and managed SQLite data are installed explicitly by the workshop loader. It needs the G05 connection operations build or later.

  1. Follow the SQLite data controls loader instructions to install the synthetic sample. Open its connection in Connections. Run Test connection and inspect the completion time. Reload the page; the result should remain visible.
  2. Open Dependencies and tag values. The loader publishes this project during setup, so the sample named queries should appear as both draft and published references. Refresh diagnostics after later query edits or publication.
  3. Rename the connection and save. Its ID stays unchanged, so named queries continue to use it. The previous test result disappears because the saved revision changed.
  4. Open the same connection in two Designer tabs. Save a rename in the first. Saving the older entry from the second should report a conflict. Use Reload in that tab to discard the older edit and inspect the new name.
  5. Clear Connection enabled, then save. New named-query executions should fail with an explicit disabled-connection message; the managed SQLite file and reference list remain intact. The Test, Create database and Browse schema actions are unavailable while disabled.
  6. Enable and save the entry, then test it. Queries should work again without recreating the database. Wait more than 30 seconds in diagnostics; the stale marker should appear. Refresh to replace it with a new snapshot timestamp.

For the optional OPC UA lab, use a dedicated read-only test server and a configured tag. Verify its value, quality and source timestamp in quick watch. Disable and save the connection: the tag should immediately show Bad_Disabled, and its subscription group should stop. Re-enable it and wait for a fresh good notification. Do not infer that a PLC or process has stopped when its client connection is disabled.

Verification

node tools/test-gateway-connections.mjs --model exercises legacy defaults, revision conflicts, credential protection, overlapping/stale tests, restart persistence, disabled subscription behavior and archived published-only dependencies with authored local fixtures.

node tools/test-gateway-connections.mjs requires disposable test accounts in the ignored test-auth file and accepts loopback port 5091 only. It verifies administrator boundaries, SQLite test/rename/disable/re-enable behavior, query references and disabled OPC UA quality. Its fixture connections are left disabled and its test project is archived; it never changes port 5090 or writes to equipment.